Your Location:Home > Gaussmeter > G93 Handheld 3-Axis Gaussmeter

G93 Handheld 3-Axis Gaussmeter

Type:Gaussmeter

Descrition:PRICE FROM $
BENEFIT RATING:★★★★★

  • Description
  • Product literature
  • Applications
  • Buy
 Coliy Gaussmeter Model List
 
Model Sensor Type Axis Accuracy
Based on reading
MAX
Range
Best
Resolution
Gaussmeters for High Magnetic Field(0-10T)
G91 Hall Handheld 1 2.0% 2T 10μT
G92 Hall Handheld 1 1.0% 10T 10μT
G93
(with probe Y08P150G93)
Hall Handheld 3 1.0% 3T 1μT
G201 Hall Desktop 1 0.25% 10T 1μT
G203 Hall Desktop 3 0.25% 3T 1μT
G401* Hall Desktop 1 0.05% 10T 0.1μT
G403* Hall Desktop 3 0.05% 3T 0.1μT
G501* Hall Desktop 1 0.01% 3T 0.1μT
GSP301 Hall Digital Transmitter 1 1%, 0.5%, 0.25%,0.05%* 10T 0.1μT
GSP303 Hall Digital Transmitter 3 1%, 0.5%, 0.25%*,0.05%* 3T 0.1μT
Gaussmeters for Low Magnetic Field(0- 4.5mT)
GMR50 GMR Handheld 1 1.0% 4.5mT 10nT
G93
(with probe Y08L150G93)
GMR Handheld 3 1.0% 1mT 10nT
GF601 Fluxgate Handheld 1 0.5% 1mT 1nT
GF603 Fluxgate Handheld 3 0.5% 1mT 1nT
GF803* Fluxgate Desktop 3 0.1% 1mT 0.1nT
GFP703 Fluxgate Digital Transmitter 3 0.5% 1mT 1nT
GFP903* Fluxgate Digital Transmitter 3 0.1% 1mT 0.1nT
Magnetic Field Measurement System
GAS3000 Probe Array of Magnetic Field Detection System:
can be used to simultaneously monitor 2- 128 points of magnetic field
Gaussmeter Calibration System DC Magnetic Field
(Accuracy up to 50ppm)
AC Magnetic Field
(Accuracy up to 0.1%)
·Low Range: 0.1nT- 0.1mT
·Middle Range: 0.1- 100mT
·High Range: 1mT- 2T
·Low Range: 0.1μT- 0.1mT
·Middle Range: 0.01- 15mT
·High Range: 0.1- 200mT
AC Magnetic Field Sensor
AMS-2K Range of 3mT; Frequency response 25Hz- 2kHz
AMS-1M Range of 3mT; Frequency response 2kHz- 1MHz
Note: 1T= 10KG; 1mT= 10G;  1μT= 10mG;  1nT= 10μG;    
 “*”: coming soon without notice.
 

 G93 Handheld 3-Axis Gaussmeter





 








 

Description: 

With 15 years of magnetic field testing experience, G93 Handheld 3-Axis Gaussmeter, introduced by COLIY, is designed for scientific research institutions, universities, laboratories, industry, manufacturing and other users. G93 Gaussmeter boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results (Max/ Min/ Peak/ Hold/ Alarm/ Polarity, XYZ components and vector of Magnetic Flux Intensity, and Trend Graph etc.).

There is a unique feature for 3-axis probe of G93: With the MEMS manufacturing technology, 3-axis probe sensor provides very high spatial resolution(0.1*0.1*0.1mm³)  and high angular accuracy (orthogonality error < 0.05°), and the thickness of 3-axis probe is 2mm. So Handheld 3-Axis Gaussmeter G93 could fulfill almost all kinds of applications of institutes, universities and high technology enterprises.

Gaussmeter G93 has high-range probe and low-range probe. Gaussmeter G93 with low-range probe allows measurements up to 10G(1mT) with the reading-based accuracy of 1%, the resolution of 0.1mG(10nT), and the frequency response of DC~ 100Hz; Gaussmeter G93 with high-range probe allows measurements up to 30KG(3T) with the reading-based accuracy of 1%, the resolution of 0.01G(1μT), and the frequency response of DC~ 1kHz; Besides, Gaussmeter G93 with double-sensor probe(hybrid probe) has two above features, and measurement range spans 108 from 10nT to 3T,  suitable for low-intensity magnetic field(like Earth magnetic field) and high-intensity magnetic field.

Temperature sensor-contained probes(probes with built-in temperature sensor) have the function of temperature compensation, so temperature sensor-contained probes are strongly recommended for better precision and stability when the temperature changes. G93 could be equipped with different kinds of 3-Axis Probes: Double-sensor 3-Axis Probe (Hybrid 3-Axis Probe), High-range 3-Axis Probe, Low-range 3-Axis Probe, and Temperature sensor-contained 3-Axis Probe.

 

   Features
 • Ergonomically designed
 • Colorful display style 
 • GUI Operation System
 • 3.2 inches color touch LCD 
 • Full 5 display digits
 • Max/Min/Hold Function
 • Smart record and review
 • Display trend graph & Alarm
 • Display XYZ components and vector 
 • S or N Polar indication
 • Rechargeable batteries can work >24h
 • Measurement range spans 108 
 • Range from 10nT(0.1mG) to 3T(30KG)
 • Accuracy: 1% of reading
 • Frequency response: DC to 1kHz
 • High orthogonality accuracy (< 0.05°)
 • High spatial resolution(0.1*0.1*0.1mm³)
 • Typical temperature coefficient 500ppm/°C
 • Probes with temperature compensation function available
 • Thickness of 3-axis probe: 2mm
 


 


  
















G93 Gaussmeter Specification:

 
Model G93
Measurement Specification
Accuracy(DC) 1% of reading ± 0.1% of the selected range
Range [Low Range]SENSOR 1: 10G(1mT)
[High Range]SENSOR 2: 30KG(3T)
(manually switch range)
Best Resolution DC [Low Range]SENSOR 1: 0.1mG(10nT); 
[High Range]SENSOR 2: 0.01G(1μT)
AC [Low Range]SENSOR 1: 1mG(0.1μT);  
[High Range]SENSOR 2: 0.01G(1μT)
Display Digits 5
Display Resolution Display Range
0~ 9999.9mG
 
0.1mG(0.01μT)
10.00G~ 999.99G 0.01G(1μT)
1.0000KG~ 9.9999KG 0.1G(0.01mT)
10.000KG~ 29.999KG 1G(0.1mT)
Frequency Response[fT] [Low Range]SENSOR 1: DC - 100Hz
[High Range]SENSOR 2: DC - 1kHz
Typical Temperature Coefficient <±500ppm/℃ (Regular 3-axis probe)
<±100ppm/℃ (Probe with temperature sensor)
Zero Drift [Low Range]SENSOR1: ±1mG/8 hours
[High Range]SENSOR2: ±0.3G/8 hours
Minimum Magnitudes for Rated AC Accuracy [Low Range]SENSOR1: >100mG
[High Range]SENSOR2: 3% of the selected range
Long-term Instability [Low Range]SENSOR1: <±2mG
 ( >0.3G, Within 8 hours, 25℃)
[High Range]SENSOR2: <±0.05% of reading
 ( >1KG, Within 8 hours, 25℃)
MAX/ MIN Acquisition Time(DC) 10ms
Front Panel
Screen 3.2 inches colorful tough LCD,320x240 Pixel
Units Gauss(G), Tesla(T), Amperes per meter (A/m)
Display Update Rate 3 readings/second
Display Mode DC, AC, XYZ Display mode, MAX., MIN, Alarm, Polarity Indication, Trend Graph etc.
Panel Feature Color resistive touch screen
Probe
Probes Double-sensor 3-Axis Probe (Hybrid 3-Axis Probe), High-range 3-Axis Probe, Low-range 3-Axis Probe,  Temperature sensor-contained 3-Axis Probe
USB Interface
Function To connect PC with gaussmeter host for monitoring the measurement
Data Update Rate MAX. 30 Sample/s
Software/ Driver SMART PC Software without any driver
Host Specifications
Ambient Temperature +15°C  to  +35°C (Rated Accuracy)
-10°C  to  +60°C (Reduced accuracy)
Storage Temperature - 20°C  to  +75°C
Ambient Magnetic Field <100 G DC
Battery Rechargeable 4500mAH Li-ion
Operating battery life >24 hours(Standard Testing Environment)
Dimension 238 mm W × 95 mm H × 42 mm D
Weight 350g
Certification CE Certification, EMC Certification
 


Probes Specification



Model G93 Gaussmeter Probes
Probe Model Max Range Resolution   Frequency
  Response
Stem dimension (mm) Working temp. (°C) DC Accuracy
(Based on reading at 25°C)
Stem material
Double-sensor Probe
Y08HY150G93
Y08HY150G93T
Sensor1: 10G(1mT)
 
Sensor2: 30KG(3T)
Sensor1:
0.1mG
 
Sensor2:
 0.01G
DC -1kHz 80*5*2 -20 - +75 1% Plastic
High-range Probe
Y08P150G93
Y08P150G93T
30KG
(3T)
0.01G
(1μT)
DC -1kHz 80*5*2 -20 - +75 1% Plastic
Low-range Probe
Y08L150G93
10G
(1mT)
0.1mG
(10nT)
DC -100Hz 80*5*2 -20 - +75 1% Plastic
 
Note:
1, Option  “T” : Temperature sensor contained Probe, has the function of temperature compensation, and the temperature coefficient is <±100ppm/℃;
2, High-range probe and double-sensor probe’s fully calibrated measurement range: ≤±20KG(±2T);

 

 
The position of sensor center

 
 
Optional Accessories

Model Descriptions
ZC10 Zero chamber, provides up to 80 dB attenuation in fields up to 500 G and can be used with standard probes. Internal dimension of the Chamber: diameter 6.8mm x 44.5mm
SAMRT PC Software PC SOFTWARE for Gaussmeter
STD30 Bracket for main unit
GHOLD100 3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, positioning accuracy of 0.1mm; center load: 10kg; weight: 3.5kg
 
    
The most popular Package
ORDER G9301: Gaussmeter G93 + Probe Y08P150G93
ORDER G9302: Gaussmeter G93 + Probe Y08P150G93 + Zero Chamber ZC10
 
 
Description Of Probe Type Selection

Y 08 P 150 G93 T
PROBE TYPE
 

A - AXIAL
T - TRANSVERSE
X - 2 AXIS
Y - 3 AXIS
 
STEM
LENGTH
 

06 - 6 cm
08 - 8 cm
10 - 10 cm
25 - 25 cm
 
PROBE STYLE
 

C – CRYOGENIC
F – FLEXIBLE
H – HIGH TEMP.
L – LOW FIELD
M – METAL
P – Plastic
U – ULTRATHIN
W – WIDE FIELD
CABLE
LENGTH
 

150 – 150cm
GAUSSMETER MODEL
 

G91 – G91 probe
G92 – G92 probe
G93 – G93 probe
 
TEMPERATURE
COMPENSATED
 

T - YES
BLANK - NO



Precision Description Of COLIY Gaussmeter

• When using gaussmeter to measure magnetic field in the environment that ambient temperature changes obviously, it’s recommended to use temperature sensor contained probe with the gaussmeter. Temperature sensor contained probe has the function of temperature compensation for better precision and stability when the temperature changes.
 

• Difference of rated accuracy between COLIY Gaussmeter and other brand’s Gaussmeters: the accuracy of COLIY is based on the reading, but other brand’s Gaussmeters’ accuracy is based on the selected range. So COLIY Gaussmeter’s measurement data is more accurate than other brand’s Gaussmeters’ when all the Gaussmeters’ accuracy is in a same value, and all the Gaussmeters work under the same working conditions. For example: When using COLIY gaussmeter and other brand gaussmeter, whose rated accuracy is 1%, to detect a magnetic field at 500G, COLIY gaussmeter readings range is 500G ± 500 * 1%, but other brand’s gaussmeter readings range is 500G ± 3000 * 1%, (3000G is the most appropriate range in such condition).
 
 
Compare With Competitors

COLIY has
an advantage
COLIY
 G93 + Probe Y08HY150G93

 
COLIY
 G93 + Probe Y08P150G93

 
Metrolab
 THM1176-MF-PDA
Accuracy(DC) 1% of reading 1% of reading 1% of reading
Range 30KG
(3T)
30KG
(3T)
30KG
(3T)
Best Resolution 0.1mG
(0.01µT)
0.01G
(1µT)
1G
(0.1mT)
Polarity Display YES YES NO
Probe dimension(mm) 80 x 5 x 2 80 x 5 x 2 16.5 x 5 x 2.3
Probe Cable 1.5m typical,
10m maximum
1.5m typical,
10m maximum
3m typical,
6m optional

G93 Handheld 3-Axis Gaussmeter 
COLIY Gaussmeter  CE  Certification

 
Compare With Competitors
 
COLIY has
an advantage
COLIY
MODEL G93 with hybird probe
Metrolab
MODEL THM1176-MF-PDA
Metrolab
MODEL THM1176-LF-PDA
Accuracy 1% 1% 1%
Range 0.1mG(0.01µT) - 30KG(3T) 1G (0.1mT) - 30KG(3T) 20mG (2 µT) - 80G(8 mT)
Best Resolution 0.1mG(0.01µT) 1G (0.1mT) 20mG (2 µT)
Probe dimensions 80 x 5 x 2mm 113 x 16 x 10 mm 113 x 16 x 10 mm
Operation graphical interfaces button button
Polar indication YES NO NO
Smart record and review YES NO NO
Temperature coefficient <100ppm/℃ after temperature compensation 500-800ppm/℃ 500-800ppm/℃
PRICE USD5000 USD6500-7000 USD5800-6000
 In terms of functionality, G93 with hybird probe = THM1176-MF-PDA + THM1176-LF-PDA

Service commitment

1.    Quick-shipment

Equipment in stock will be shipped out in 5 work days after payment effected.

2.    30 Days Full-refund Guarantee

Unconditional refund in 30 days after the shipment date.(Buyer pays return shipping)   

3.    12 Months Warranty

Warranty service period up to 12 months since the shipment

4.    OEM & ODM

Best qualiy product with your own brand: we can design for you, manufacture for you!
 

COLIY ASIA LIMITED BANK INFORMATION:
 
BANKValartis Bank (Liechtenstein) AG
BANK ADDRESS: Schaaner Strasse 27, 9487 Gamprin-Bendern, Liechtenstein
ACCOUNT NAMEColiy Asia Limited
IBAN USD accountLI92 0880 3103 4361 0000 0
IBAN EUR accountLI65 0880 3103 4361 0000 1


 
Delivery1-2 weeks

 
How to place the order:
Please send your purchase order, company and shipping address information to sales@coliy.com