Your Location:Home > Gaussmeter > GF603 Three-Axis Fluxgate Magnetometer

GF603 Three-Axis Fluxgate Magnetometer

Type:Gaussmeter

Descrition:PRICE FROM ---
BENEFIT RATING:★★★★★

  • Description
  • Product literature
  • Applications
  • Buy
 Coliy Gaussmeter Model List
 
Model Sensor Type Axis Accuracy
Based on reading
MAX
Range
Best
Resolution
Gaussmeters for High Magnetic Field(0-10T)
G91 Hall Handheld 1 2.0% 2T 10μT
G92 Hall Handheld 1 1.0% 10T 10μT
G93
(with probe Y08P150G93)
Hall Handheld 3 1.0% 3T 1μT
G201 Hall Desktop 1 0.25% 10T 1μT
G203 Hall Desktop 3 0.25% 3T 1μT
G401* Hall Desktop 1 0.05% 10T 0.1μT
G403* Hall Desktop 3 0.05% 3T 0.1μT
G501* Hall Desktop 1 0.01% 3T 0.1μT
GSP301 Hall Digital Transmitter 1 1%, 0.5%, 0.25%,0.05%* 10T 0.1μT
GSP303 Hall Digital Transmitter 3 1%, 0.5%, 0.25%*,0.05%* 3T 0.1μT
Gaussmeters for Low Magnetic Field(0- 4.5mT)
GMR50 GMR Handheld 1 1.0% 4.5mT 10nT
G93
(with probe Y08L150G93)
GMR Handheld 3 1.0% 1mT 10nT
GF601 Fluxgate Handheld 1 0.5% 1mT 1nT
GF603 Fluxgate Handheld 3 0.5% 1mT 1nT
GF803* Fluxgate Desktop 3 0.1% 1mT 0.1nT
GFP703 Fluxgate Digital Transmitter 3 0.5% 1mT 1nT
GFP903* Fluxgate Digital Transmitter 3 0.1% 1mT 0.1nT
Magnetic Field Measurement System
GAS3000 Probe Array of Magnetic Field Detection System:
can be used to simultaneously monitor 2- 128 points of magnetic field
Gaussmeter Calibration System DC Magnetic Field
(Accuracy up to 50ppm)
AC Magnetic Field
(Accuracy up to 0.1%)
·Low Range: 0.1nT- 0.1mT
·Middle Range: 0.1- 100mT
·High Range: 1mT- 2T
·Low Range: 0.1μT- 0.1mT
·Middle Range: 0.01- 15mT
·High Range: 0.1- 200mT
AC Magnetic Field Sensor
AMS-2K Range of 3mT; Frequency response 25Hz- 2kHz
AMS-1M Range of 3mT; Frequency response 2kHz- 1MHz
Note: 1T= 10KG; 1mT= 10G;  1μT= 10mG;  1nT= 10μG;    
 “*”: coming soon without notice.
 

GF603 Three-Axis Fluxgate Magnetometer 
 
 
Description: 

Three-axis Fluxgate Magnetometer GF603, made by COLIY, has the excellent ergonomic design with the latest electronic technology, and it’s one of best choices to measure low-intensity magnetic field. This handheld fluxgate magnetometer can be used in geomagnetism detection, wrapped detection, traffic monitoring, measuring residual magnetism, low-intensity magnetic field measurement, etc. GF603 boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results (Max/ Min/ Peak/ Hold/ Alarm/ Polarity, XYZ components and vector of Magnetic Flux Intensity, and Trend Graph etc.).

Magnetometer GF603 can be used to detect low-intensity magnetic field in DC measurement mode and AC measurement mode respectively: GF603 allows DC measurements with the reading-based accuracy of 0.50%, resolution of 0.01mG(1nT) and AC measurement with the reading based accuracy of 1%, resolution of 0.1mG(10nT), and frequency response range of DC~ 1KHz. In addition, Gaussmeter GF603 could be equipped with 3-Axis Probes of different range: ±1G(±100μT), ±5G(±500μT) and ±10G(±1mT).
 
 
Features
 • Ergonomically designed
 • Colorful display style 
 • GUI Operation System
 • 3.2 inches color touch LCD 
 • Full 5 display digits
 • Max/Min/Hold Function
 • Display trend graph & Alarm
 • Display XYZ components and vector 
 • S or N Polar indication
 • Range: ±1G, ±5G and ±10G
 • DC Accuracy: 0.50% of reading
 • AC Accuracy: 1% of reading
 • AC measurement mode
 • Frequency response: DC- 1KHz
 • Stability: ±2nT (>1μT, within 8 hours, 25 ℃)
 • Smart record and review
 • USB Interface port
 • Rechargeable batteries can work >24h
 
 
 
 
 
 
 
 



 
 
 
GF603 Magnetometer Specification:

Model GF603
Measurement Specification
Accuracy DC ±0.50% of reading ± 0.05% of Full Scale
AC ±1% of reading ± 0.05% of Full Scale, when fT < 400Hz;
±2% of reading ± 0.05% of Full Scale, when fT < 600Hz;
±7% of reading ± 0.05% of Full Scale, when fT < 1000Hz
Range X,Y,Z DC ±1G
(±100,000nT)
±5G
(±500,000nT)
±10G
(±1,000,000nT)
AC* ±0.7G
(±70,000nT)
±3.5G
(±350,000nT)
±7G
(±700,000nT)
R DC 1.73205G
(173,205nT)
8.66025G
(866,025nT)
17,3205G
(1,732,050nT)
AC* 1.2124G
(121,240nT)
6.0622G
(606,220nT)
12.124G
(1,212,400nT)
Best Resolution X, Y, Z, R DC 0.01mG(1nT) 0.05mG(5nT) 0.1mG(10nT)
AC 0.1mG(10nT) 0.5mG(50nT) 1mG(100nT)
Display Digits 5
Display Resolution Display Range
0~ 999.9mG
 
0.01mG(1nT)
1.000G~ 9.999G 0.1mG(10nT)
Frequency Response [fT] DC - 1KHz
Typical Temperature
Coefficient
<±100ppm/℃
Hysteresis <2nT for exposure to up to 2 x full scale
Zero Drift ±2nT/ 8 hours
Minimum Magnitudes
for Rated AC Accuracy
>10mG
Long-term Instability <±2nT (>1μT, within 8 hour, 25℃)
MAX/ MIN Acquisition
Time(DC)
0.01s
Front Panel
Screen 3.2 inches colorful tough LCD,320x240 Pixel
Units Gauss(G), Tesla(T), Amperes per meter (A/m)
Display Update Rate 3 readings/second
Display Mode DC, AC, XYZ Display mode, MAX, MIN, Alarm, Polarity Indication, Trend Graph etc.
Panel Feature Color resistive touch screen
Probe
Probes 3-Axis Fluxgate Probe
USB Interface
Function To connect PC with gaussmeter host for monitoring the measurement
Data Update Rate MAX. 30 Sample/s
Software/ Driver SMART PC Software without any driver
Host Specifications
Ambient Temperature +15°C  to  +35°C (Rated Accuracy)
-10°C  to  +60°C (Reduced accuracy)
Storage Temperature - 20°C  to  +75°C
Ambient Magnetic Field <100 G DC
Battery Rechargeable 4500mAH Li-ion
Operating battery life >24 hours(Standard Testing Environment)
Dimension 238 mm W × 95 mm H × 42 mm D
Weight 350g
Certification CE Certification, EMC Certification
 
“*”: AC Range mentioned above refers to AC magnetic field measurement range after DC magnetic field is shielded, so if DC magnetic field is not shielded, and users want to measure magnetic field in AC measurement mode, AC Range is equivalent to the value that 0.7 times of DC Range minus DC magnetic field intensity. [sqrt(2)/2 ≈ 0.7]
 

Probes Specification
 

Model GF603 Magnetometer Probes
Probe Model Range Resolution
(X, Y, Z, R)
Frequency
Response
Stem dimension
(mm)
Working temp. (°C) DC Accuracy
(Based on reading at 25°C)
Stem material
X, Y, Z Axis Vector R
GF-Y01 ±100,000nT
(±1G)
173,205nT 1nT
(0.01mG)
DC-1KHz 107 x 32 x 32 -20 - +60 0.50% Plastic
GF-Y05 ±500,000nT
(±5G)
866,025nT 5nT
(0.05mG)
DC-1KHz 107 x 32 x 32 -20 - +60 0.50% Plastic
GF-Y10 ±1,000,000nT
(±10G)
1,732,050nT 10nT
(0.1mG)
DC-1KHz 107 x 32 x 32 -20 - +60 0.50% Plastic
 
Note:
1, Three-axis fluxgate probe can be customized within ±10G(±1mT) measurement range;
2, Unit Conversion: 1T=10,000G

 
 
Optional Accessories

Model Descriptions
SAMRT PC Software PC SOFTWARE for Gaussmeter/Magnetometer
STD30 Bracket for main unit
GHOLD100 3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, positioning accuracy of 0.1mm; center load: 10kg; weight: 3.5kg 

     
The most popular Package
ORDER GF60301: Magnetometer GF603 + Probe GF-Y01 
ORDER GF60305: Magnetometer GF603 + Probe GF-Y05
ORDER GF60310: Magnetometer GF603 + Probe GF-Y10
 

Description Of Probe Type Selection

GF Y 01
PROBE PRINCIPLE
 
GF- Fluxgate Probe

 
PROBE TYPE
 
Y- Three-axis Probe
T- Transverse Probe
A- Axial Probe
MEASUREMENT RANGE
 
01- Range of 1G
05- Range of 5G
10- Range of 10G
 
 
Compare With Competitors

COLIY has
an advantage
COLIY
 GF603
MEDA
 FVM400
MAX Range 10G
(1000μT)
1G
(100μT)
DC/AC Measurement Mode DC Mode & AC Mode DC Mode
Best Resolution 10μG
(1nT)
10μG
(1nT)
Frequency Response DC- 1KHz DC- 100Hz
Operation System GUI Button Control
Polar indication YES NO
Smart record and review YES NO
Alarm Function YES NO
 
GF603 Three-Axis Fluxgate Magnetometer

COLIY Gaussmeter  CE  Certification

Service commitment

1. Quick-shipment

Equipment in stock will be shipped out in 5 work days after payment effected.

2. 30 Days Full-refund Guarantee

Unconditional refund in 30 days after the shipment date.(Buyer pays return shipping)

3. 12 Months Warranty

Warranty service period up to 12 months since the shipment

4. OEM & ODM

Best qualiy product with your own brand: we can design for you, manufacture for you!


COLIY ASIA LIMITED BANK INFORMATION:

BANKValartis Bank (Liechtenstein) AG
BANK ADDRESS: Schaaner Strasse 27, 9487 Gamprin-Bendern, Liechtenstein 
ACCOUNT NAMEColiy Asia Limited
IBAN USD accountLI92 0880 3103 4361 0000 0
IBAN EUR accountLI65 0880 3103 4361 0000 1



Delivery2-4 weeks


How to place the order: 
Please send your purchase order, company and shipping address information to sales@coliy.com